Connect equipment already on site as well as new sensors to the same platform, without requiring you to replace your instrumentation.
The TERA 360 Gateway adapts to two very different field realities: supervising a controlled environment, and running an air handling unit.
In a controlled environment, someone is physically present to check conditions. The TERA 360 Gateway installs a visible supervision point there, fed by the Bluetooth sensors of the SENS range.
The whole SENS range over Bluetooth 4.2 / BLE, plus LoRa for measurement points out of reach — no cabling to pull.
Thresholds, alerts and current values are visible directly on site, for the teams present in the environment.
The last 24 hours of readings stay available on the screen, with no need to open the platform.
In case of a network outage, data stays stored locally for 48 hours and syncs back once reconnected — nothing is lost.
In a technical room, the gateway sits inside a cabinet — nobody sees it or checks its screen. What matters is that Modbus sensor data flows back reliably, with wiring kept as simple as possible.
The PROB range over Modbus RTU — ePMDUCT, DeltaP, T/RH, CO₂, air speed, energy meter — via the ModLinkChainer RS485 interface card.
ModLinkChainer powers and daisy-chains multiple Modbus sensors on a single PoE line — no proprietary cabling or dedicated power supply needed.
Modbus slave ports let a PLC or an existing BMS query the gateway directly.
In case of a network outage, data stays stored locally for 48 hours and syncs back once reconnected — nothing is lost.
On-site display and alarms.
Three ports, master or slave mode.
On a single RJ45 cable, via ModLinkChainer.
4G / GSM for the cloud uplink.
See how the Gateway collects, displays and transmits data from all your sensors.
TERA 360 connects to a wide range of off-the-shelf probes, wired and radio alike. The point is not to replace your instrumentation: it is to start from what is already installed, then fill in wherever a measurement is missing.
Temperature · Humidity
CO₂ · Temperature · Humidity · Barometric pressure
Temperature
Differential pressure
Occupancy
Temperature · Humidity
CO₂ · VOC · Temperature
Temperature · Humidity · Wind · Barometric pressure · Rainfall
Presence · Motion
Thermal energy
Leak detection
Soil moisture · Temperature · Electrical conductivity
Your current Modbus probes (temperature, humidity, pressure, CO₂, energy…) connect directly to the ModLinkChainer — no replacement, no re-wiring. The Gateway auto-detects and integrates each sensor in minutes.
Request a live demo of the platform.